Are We Treating Risk, Or Treating Every Incision the Same Way?

Jun 25, 2026

We sort patients into “low risk” and “high risk” for everything from VTE to cardiac events to SSI. Then  when it comes to single use NPWT, a high-risk wound and a low risk wound often get the same device at the same pressure. 

That doesn’t fit with what the newer data is showing.

If you were to listen to any pre-op briefing on a busy day you would notice how much of it is about risk: BMI, diabetes, smoking, previous infections, whether the case is a revision or a straight-forward primary or the complexity of the case. The language of risk is everywhere. We routinely build that into our orders for antibiotics, anticoagulation, monitoring and follow up orders. What is not heard as often is how that same risk profile is used when we decide which NPWT system goes on the incision and at what pressure setting.

In three recent studies that focused on higher risk obese C-section patients and large groups of orthopedic and cardiovascular patients. The -80 mm/Hg single-use NPWT device pressure kept showing a similar pattern: 

  • In orthopedic and cardiovascular surgery of over 22,000 patients, the -80 mm/Hg device was associated with lower odds of dehiscence and lower overall healthcare use, without any clear signal that other surgical site complications were worse.

“The -80 mmHg device was associated with significantly lower HCRU (Healthcare resource use) and likelihood of dehiscence after orthopaedic and cardiovascular surgery versus the -125 mm/Hg device and there were no differences in other SSC’s.” (Bashyal RK, et al., J Wound Care, 2025)

  • In more than 10,000 cesarean deliveries (5,332 women in each arm), the -80 mm/Hg group had lower rates or overall SSI, superficial SSI, dehiscence, seroma, and lower costs compared with the -125 mm/Hg device, with no meaningful differences in deep SSI, hematoma, or length of stay.

“Overall SSI, superficial SSI, dehiscence, seroma and costs were significantly lower with the -80 mm/Hg pressure setting compared with the -125 mm/Hg pressure setting (P < 0.5). There were no differences between the 2 pressure settings observed for hematoma, deep SSI, and LOS (P > .05).” (Vilkins AL et al., Wounds, 2025)

  • In obese C-section patients across randomized trials, the -80 mm/Hg device showed a statistically significant reduction in composite SSI and superficial SSI versus standard dressings, while the same SSI benefit was not demonstrated with the -125 mm/Hg device. 

“A statistically significant improvement in the composite SSI (odds ratio (OR): 0.69; 95% confidence interval (CI): 0.54-0.89) and superficial SSI (OR: 0.66; 95% Cl: 0.50-0.86) outcomes was observed with the -80 mm/Hg device, compared with standard dressings.  The same effect on SSI outcomes was not observed with the -125 mm/Hg device (composite SSI-OR: 0.91; 95% Cl: 0.64-1.28; superficial SSI-OR:1.12; 95% Cl: 0.70-1.78).” (Goldman T, Costa B. A Systematic Review and Meta-analysis of Two Negative Pressure Wound Therapy Devices to Manage Cesarean Section Incisions. AM J Perinatol. 2024 May;41(S 01):e2786-e2798. doi: 10.1055/s-0043-1775562.) 

That doesn’t mean every incision automatically should be on -80 mm/Hg. It does mean that, at least when working with these higher risk patients, the choice of pressure setting should be an important part of the conversation. This is one more part of risk management that deserves a real discussion. 

The question that should be popping up is simple: If we are already doing the work to flag which patients are high risk, why isn’t that same risk conversation happening when we decide the NPWT pressure setting and what that patient actually gets?

Transparency statement: What is summarized here comes from peer reviewed studies that report associations between specific single use NPWT devices/and their pressure settings/outcomes like SSI, dehiscence, seroma, healthcare use, and cost in the patient groups they studied. These studies do not prove that any one device or pressure setting will produce the same results for every patient or every hospital. They reflect what was seen in those large data sets and trials. The final choice still belongs with the treating team, using clinical judgment, patient specific factors, and their local protocols.